KUHLWERXIndustrial Cooling Systems
Request a Quote

Home / Equipment / Ripening and Pre-Cooling Coolers

Ripening and Pre-Cooling Coolers

Differential pressure coolers for forced-air pre-cooling and ripening rooms. Air is drawn through the stacked load instead of around it, so fruit at the center reaches temperature with fruit at the face. Bananas ripen at 57 to 63°F and avocados at 68 to 75°F. The room has to hold the number the fruit needs.

Best for Banana and avocado ripening rooms and forced-air pre-cooling of packed produce.

Low profile differential pressure unit cooler with four downward facing fans and an open access panel showing copper return bends.
Photo slotripening-unit-cooler-1600.jpg

Differential Pressure Cooler

Low profile, four fans firing downward, EC motors and a coated fin block, with a reversible fan plate.

UL approvedEC fans, 60 Hz Aluminum / copper / stainless
Low profile unit cooler with four fans set into the top panel and a tall aluminum fin block.
Photo slotripening-cooler-1600.jpg

Ripening Room Cooler

Low profile, four fans set into the top panel and a tall aluminum fin block, to keep ceiling height for product.

UL approvedEC fans, 60 Hz Aluminum / copper / stainless

Configurations

Differential pressure unit cooler built for high airflow through a stacked load in a low profile housing.
Photo slotprecooling-cooler-1600.jpg

Forced-Air Pre-Cooler

High airflow through a stacked load in a low profile housing, so field heat comes out of the whole pallet together.

Specifications

US units, 60 Hz power. Marked values are confirmed against the selected model before they go on a quote.

Airflow path
Fully two-way, through the load
Fans
EC
Casing
Galvanized steel, spray coated
Fan plate
Reversible
Capacity
[SPEC - CONFIRM]
Airflow
[SPEC - CONFIRM]
Dimensions
[SPEC - CONFIRM]
Approval
UL approved
ULISO 9001CEEACRoHS

Models and codes

Built per project. The code is issued with your selection.

How to read the code

KRC-R-02x25-0120
  1. KRCRipening and pre-cooling cooler
  2. RDuty. R ripening, P pre-cooling
  3. 02x25Fans, then fan diameter in inches
  4. 0120Selected capacity, MBH, at your room load

60 Hz. EC fans on 208-230 V/1/60, 208-230 V/3/60 or 460 V/3/60. 49 in fans and larger on a VFD.

Questions buyers ask

All questions

What is a differential pressure cooler?

A cooler that draws air through stacked pallets of produce instead of around them, so fruit at the center of the load reaches temperature with fruit at the face.

What temperatures does ripening need?

Bananas ripen at 57 to 63°F and avocados at 68 to 75°F. The room has to hold the number the fruit needs.

Request a quote

Send us the heat load.

Fluid, flow, ambient and the space you have. A sized selection comes back with the approval marks confirmed.

Request a Quote

A person reads it. Send the heat load and a selection comes back.