Dry Coolers
208 to 14,546 MBHReject process heat to the air. No tower, no makeup water, no basin.
Questions first? sales@kuhlwerx.com
Industrial process cooling
UL approved dry coolers, condensers, unit coolers and heat exchangers. Over 14,500 MBH per unit. Send the heat load and an engineer sizes it.

Selector
Most sizing tools sit behind a login. This one does not. Three questions and your numbers, and the right family comes back with your conditions already attached to the quote.
The equipment
Heat rejection, room cooling, freezing, ripening and coils built to print. One quote covers the loop.
01 08

Reject process heat to the air. No tower, no makeup water, no basin.

Condense refrigerant outdoors on a V-bank that keeps the footprint down.

CO2 gas coolers and oil coolers, on the same coil and fan platforms.

Hold air temperature in a room that has to stay at a number.

Throw air two ways from one low unit, where a single throw leaves a warm end.

Pull product down to frozen fast, in a spiral, a tunnel or a freezing room.

Push air through the stacked load, not around it, so the whole pallet moves together.

When nothing standard fits the duty, the fluid or the space.
The job
Nobody calls about cooling when things are going well. These are the four calls we take most.
It fails on the hottest day because that is the day it works hardest. Size it to your real design ambient and it holds.
Makeup water, treatment chemicals, blowdown, basin cleaning and the paperwork behind all of it. A dry cooler runs on air.
Out of spec fluid means out of spec parts, and the scrap is yours. Hold the loop temperature and the parts hold tolerance.
By then the line has been down twice. Send the heat load and a selection comes back.
Rack density climbs while water gets harder to permit. Free cooling hours only pay if the equipment can take them.
Generators, compressors and transformer oil all need somewhere to put their heat, usually on a site with no water worth using.
Building loads that have to hold through a summer peak without a cooling tower and the water treatment contract behind it.
Hydraulic oil runs hot and the press slows down. Coolant drifts and the tolerance goes with it.
Quench temperature decides the metallurgy. Hold it and the parts pass. Lose it and you re-run a batch that was already promised.
Process fluid comes back scorched and the product goes out of spec with it.
KUHLWERX supplies and supports UL approved industrial cooling equipment in North America: dry coolers, condensers, CO2 gas coolers, oil coolers, industrial and dual discharge unit coolers, blast freezers, ripening coolers and heat exchangers built to print, rated at 60 Hz and sized to each project.
Yes. KUHLWERX equipment is UL approved. The range also carries CE and RoHS marks.
Yes. Ratings are at 60 Hz. Units use EC fans on 208-230 V or 460 V supply, and fans of 49 in and larger run on a VFD, so rated airflow and capacity hold on US power.
27530 US-31, Flomaton, AL 36441. KUHLWERX supplies and supports equipment across North America.
No. Every unit is sized to the heat load, fluid and site conditions, so the price depends on the selection. Send the numbers and a sized quote comes back.
Request a quote
Fluid, flow, ambient and the space you have. A sized selection comes back, not a brochure.
A person reads it. Send the heat load and a selection comes back.