Condensers
Air-cooled condensers for HFC and ammonia plant, built on the same flat bed and V-bank platforms as the dry coolers. The V-bank holds the footprint down as capacity goes up.
Best for Remote air-cooled condensing on HFC and ammonia refrigeration plant, cold storage and process refrigeration.

Air-Cooled Condenser
V-bank slabs on a structural frame with lifting eyes and an electrical enclosure, sized to your condensing temperature.
Specifications
US units, 60 Hz power. Marked values are confirmed against the selected model before they go on a quote.
- Capacity, HFC
- 249 to 13,939 MBH heat rejection, rated R404A
- Capacity, ammonia
- 246 to 15,078 MBH heat rejection
- Rating point
- 95°F ambient, 122°F condensing
- Refrigerants
- R404A, R507A, R134a, R407C, R410A, ammonia. Others on request
- Configurations
- Flat bed or V-bank, single or double fan row
- Fans
- 36 to 71 in. EC, or VFD on 49 in and up
- Tube
- Copper, stainless or cupronickel
- Sound level
- [SPEC - CONFIRM]
- Power
- 60 Hz. 208-230 V or 460 V. EC fans; 49 in fans and larger on a VFD
- Approval
- UL approved
Models and codes
Every unit is selected to your fluid, flow and design ambient, so the code carries the selected capacity. Frame sizes and capacity ranges are below.
How to read the code
KCH-V1-06x36-1820-E- KCHAir-cooled condenser. KCH HFC, KCA ammonia
- V1Arrangement. F1 flat bed, one fan row. F2 flat bed, two rows. V1 V-bank, one row. V2 V-bank, two rows
- 06x36Fans, then fan diameter in inches
- 1820Selected heat rejection, MBH, at your conditions
- EFan drive. E EC fans, V VFD
60 Hz. EC fans on 208-230 V/1/60, 208-230 V/3/60 or 460 V/3/60. 49 in fans and larger on a VFD.
Capacity by frame family16 ranges
| Code | Duty | Arrangement | Fan, in | Fans | Capacity, MBH | Rated at |
|---|---|---|---|---|---|---|
| KCH-F1 | HFC condenser | Flat bed, one row of fans | 36 | 1 to 8 | 249 to 2,607 | R404A, 95°F ambient, 122°F condensing |
| KCA-F1 | Ammonia condenser | Flat bed, one row of fans | 36 | 1 to 8 | 246 to 2,658 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-F1 | HFC condenser | Flat bed, one row of fans | 49 | 1 to 8 | 566 to 5,285 | R404A, 95°F ambient, 122°F condensing |
| KCA-F1 | Ammonia condenser | Flat bed, one row of fans | 49 | 1 to 8 | 618 to 5,302 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-F1 | HFC condenser | Flat bed, one row of fans | 71 | 1 to 7 | 785 to 6,551 | R404A, 95°F ambient, 122°F condensing |
| KCA-F1 | Ammonia condenser | Flat bed, one row of fans | 71 | 1 to 7 | 894 to 6,777 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-F2 | HFC condenser | Flat bed, two rows of fans | 36 | 4 to 18 | 972 to 5,569 | R404A, 95°F ambient, 122°F condensing |
| KCA-F2 | Ammonia condenser | Flat bed, two rows of fans | 36 | 4 to 18 | 515 to 5,831 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-V1 | HFC condenser | V-bank, one row of fans | 36 | 1 to 10 | 293 to 3,982 | R404A, 95°F ambient, 122°F condensing |
| KCA-V1 | Ammonia condenser | V-bank, one row of fans | 36 | 1 to 10 | 317 to 4,211 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-V1 | HFC condenser | V-bank, one row of fans | 49 | 1 to 10 | 723 to 7,984 | R404A, 95°F ambient, 122°F condensing |
| KCA-V1 | Ammonia condenser | V-bank, one row of fans | 49 | 1 to 10 | 686 to 8,111 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-V1 | HFC condenser | V-bank, one row of fans | 63 | 1 to 10 | 1,440 to 13,939 | R404A, 95°F ambient, 122°F condensing |
| KCA-V1 | Ammonia condenser | V-bank, one row of fans | 63 | 1 to 10 | 1,491 to 15,078 | Ammonia, 95°F ambient, 122°F condensing |
| KCH-V2 | HFC condenser | V-bank, two rows of fans | 36 | 4 to 28 | 1,157 to 10,816 | R404A, 95°F ambient, 122°F condensing |
| KCA-V2 | Ammonia condenser | V-bank, two rows of fans | 36 | 4 to 28 | 1,218 to 11,188 | Ammonia, 95°F ambient, 122°F condensing |
Frames, flat bed, one fan row23 frames
| Frame | Fans | Fan, in | Length, in | Width, in | Height, in |
|---|---|---|---|---|---|
| F1-01x36 | 1 | 36 | 78 or 90 | 48 | 69 |
| F1-02x36 | 2 | 36 | 137 or 161 | 48 | 69 |
| F1-03x36 | 3 | 36 | 196 or 231 | 48 | 69 |
| F1-04x36 | 4 | 36 | 255 or 302 | 48 | 69 |
| F1-05x36 | 5 | 36 | 314 or 373 | 48 | 69 |
| F1-06x36 | 6 | 36 | 373 or 444 | 48 | 69 |
| F1-07x36 | 7 | 36 | 432 or 515 | 48 | 69 |
| F1-08x36 | 8 | 36 | 491 or 586 | 48 | 69 |
| F1-01x49 | 1 | 49 | 102 | 90 | – |
| F1-02x49 | 2 | 49 | 181 | 90 | – |
| F1-03x49 | 3 | 49 | 260 | 90 | – |
| F1-04x49 | 4 | 49 | 339 | 90 | – |
| F1-05x49 | 5 | 49 | 417 | 90 | – |
| F1-06x49 | 6 | 49 | 496 | 90 | – |
| F1-07x49 | 7 | 49 | 575 | 90 | – |
| F1-08x49 | 8 | 49 | 654 | 90 | – |
| F1-01x71 | 1 | 71 | 118 | 90 | 85 |
| F1-02x71 | 2 | 71 | 213 | 90 | 85 |
| F1-03x71 | 3 | 71 | 307 | 90 | 85 |
| F1-04x71 | 4 | 71 | 402 | 90 | 85 |
| F1-05x71 | 5 | 71 | 496 | 90 | 85 |
| F1-06x71 | 6 | 71 | 591 | 90 | 85 |
| F1-07x71 | 7 | 71 | 685 | 90 | 85 |
Frames, flat bed, two fan rows8 frames
| Frame | Fans | Fan, in | Length, in | Width, in | Height, in |
|---|---|---|---|---|---|
| F2-04x36 | 4 | 36 | 137 or 161 | 89 | 69 |
| F2-06x36 | 6 | 36 | 196 or 231 | 89 | 69 |
| F2-08x36 | 8 | 36 | 255 or 302 | 89 | 69 |
| F2-10x36 | 10 | 36 | 314 or 373 | 89 | 69 |
| F2-12x36 | 12 | 36 | 373 or 444 | 89 | 69 |
| F2-14x36 | 14 | 36 | 432 or 515 | 89 | 69 |
| F2-16x36 | 16 | 36 | 491 or 586 | 89 | 69 |
| F2-18x36 | 18 | 36 | 550 or 657 | 89 | 69 |
Frames, V-bank, one fan row30 frames
| Frame | Fans | Fan, in | Length, in | Width, in | Height, in |
|---|---|---|---|---|---|
| V1-01x36 | 1 | 36 | 60 | 45 | 68 |
| V1-02x36 | 2 | 36 | 107 | 45 | 68 |
| V1-03x36 | 3 | 36 | 155 | 45 | 68 |
| V1-04x36 | 4 | 36 | 202 | 45 | 68 |
| V1-05x36 | 5 | 36 | 249 | 45 | 68 |
| V1-06x36 | 6 | 36 | 296 | 45 | 68 |
| V1-07x36 | 7 | 36 | 344 | 45 | 68 |
| V1-08x36 | 8 | 36 | 391 | 45 | 68 |
| V1-09x36 | 9 | 36 | 438 | 45 | 68 |
| V1-10x36 | 10 | 36 | 485 | 45 | 68 |
| V1-01x49 | 1 | 49 | 76 | 79 | 93 |
| V1-02x49 | 2 | 49 | 139 | 79 | 93 |
| V1-03x49 | 3 | 49 | 202 | 79 | 93 |
| V1-04x49 | 4 | 49 | 265 | 79 | 93 |
| V1-05x49 | 5 | 49 | 328 | 79 | 93 |
| V1-06x49 | 6 | 49 | 391 | 79 | 93 |
| V1-07x49 | 7 | 49 | 454 | 79 | 93 |
| V1-08x49 | 8 | 49 | 517 | 79 | 93 |
| V1-09x49 | 9 | 49 | 580 | 79 | 93 |
| V1-10x49 | 10 | 49 | 643 | 79 | 93 |
| V1-01x63 | 1 | 63 | 110 | 106 | 121 |
| V1-02x63 | 2 | 63 | 205 | 106 | 121 |
| V1-03x63 | 3 | 63 | 299 | 106 | 121 |
| V1-04x63 | 4 | 63 | 394 | 106 | 121 |
| V1-05x63 | 5 | 63 | 488 | 106 | 121 |
| V1-06x63 | 6 | 63 | 583 | 106 | 121 |
| V1-07x63 | 7 | 63 | 677 | 106 | 121 |
| V1-08x63 | 8 | 63 | 772 | 106 | 121 |
| V1-09x63 | 9 | 63 | 866 | 106 | 121 |
| V1-10x63 | 10 | 63 | 961 | 106 | 121 |
Frames, V-bank, two fan rows13 frames
| Frame | Fans | Fan, in | Length, in | Width, in | Height, in |
|---|---|---|---|---|---|
| V2-04x36 | 4 | 36 | 107 | 89 or 110 | 97 |
| V2-06x36 | 6 | 36 | 155 | 89 or 110 | 97 |
| V2-08x36 | 8 | 36 | 202 | 89 or 110 | 97 |
| V2-10x36 | 10 | 36 | 249 | 89 or 110 | 97 |
| V2-12x36 | 12 | 36 | 296 | 89 or 110 | 97 |
| V2-14x36 | 14 | 36 | 344 | 89 or 110 | 97 |
| V2-16x36 | 16 | 36 | 391 | 89 or 110 | 97 |
| V2-18x36 | 18 | 36 | 438 | 89 or 110 | 97 |
| V2-20x36 | 20 | 36 | 485 | 89 or 110 | 97 |
| V2-22x36 | 22 | 36 | 533 | 89 or 110 | 97 |
| V2-24x36 | 24 | 36 | 580 | 89 or 110 | 97 |
| V2-26x36 | 26 | 36 | 627 | 89 or 110 | 97 |
| V2-28x36 | 28 | 36 | 674 | 89 or 110 | 97 |
Questions buyers ask
What is an air-cooled condenser?
An air-cooled condenser rejects the heat from a refrigeration system to outdoor air. Hot refrigerant gas from the compressor condenses to liquid inside a finned coil while fans move air across it.
What capacity do KUHLWERX condensers cover?
249 to 13,939 MBH heat rejection on HFC, rated R404A, and 246 to 15,078 MBH on ammonia, both at 95°F ambient and 122°F condensing.
Flat bed or V-bank?
A V-bank puts the coils in a V under the fans, so it fits more coil surface in the same footprint. Flat bed units are lower and simpler to service. Footprint, sound and capacity decide it.
Request a quote
Send us the heat load.
Fluid, flow, ambient and the space you have. A sized selection comes back with the approval marks confirmed.
A person reads it. Send the heat load and a selection comes back.