KUHLWERX Precision Cooling Solutions
Request a Quote

Questions first? sales@kuhlwerx.com

Home / Equipment / Condensers

Condensers

Air-cooled condensers for HFC and ammonia plant, built on the same flat bed and V-bank platforms as the dry coolers. The V-bank holds the footprint down as capacity goes up.

Best for Remote air-cooled condensing on HFC and ammonia refrigeration plant, cold storage and process refrigeration.

Air-cooled condenser with six axial fans and coated coil slabs in a V-bank on a steel frame, installed outside a plant building.
Photo slotcondenser-1600.jpg

Air-Cooled Condenser

V-bank slabs on a structural frame with lifting eyes and an electrical enclosure, sized to your condensing temperature.

UL approvedEC fans, 60 Hz Aluminum / copper / stainless

Specifications

US units, 60 Hz power. Marked values are confirmed against the selected model before they go on a quote.

Capacity, HFC
249 to 13,939 MBH heat rejection, rated R404A
Capacity, ammonia
246 to 15,078 MBH heat rejection
Rating point
95°F ambient, 122°F condensing
Refrigerants
R404A, R507A, R134a, R407C, R410A, ammonia. Others on request
Configurations
Flat bed or V-bank, single or double fan row
Fans
36 to 71 in. EC, or VFD on 49 in and up
Tube
Copper, stainless or cupronickel
Sound level
[SPEC - CONFIRM]
Power
60 Hz. 208-230 V or 460 V. EC fans; 49 in fans and larger on a VFD
Approval
UL approved
ULCERoHS

Models and codes

Every unit is selected to your fluid, flow and design ambient, so the code carries the selected capacity. Frame sizes and capacity ranges are below.

How to read the code

KCH-V1-06x36-1820-E
  1. KCHAir-cooled condenser. KCH HFC, KCA ammonia
  2. V1Arrangement. F1 flat bed, one fan row. F2 flat bed, two rows. V1 V-bank, one row. V2 V-bank, two rows
  3. 06x36Fans, then fan diameter in inches
  4. 1820Selected heat rejection, MBH, at your conditions
  5. EFan drive. E EC fans, V VFD

60 Hz. EC fans on 208-230 V/1/60, 208-230 V/3/60 or 460 V/3/60. 49 in fans and larger on a VFD.

Capacity by frame family16 ranges
CodeDutyArrangementFan, inFansCapacity, MBHRated at
KCH-F1HFC condenserFlat bed, one row of fans361 to 8249 to 2,607R404A, 95°F ambient, 122°F condensing
KCA-F1Ammonia condenserFlat bed, one row of fans361 to 8246 to 2,658Ammonia, 95°F ambient, 122°F condensing
KCH-F1HFC condenserFlat bed, one row of fans491 to 8566 to 5,285R404A, 95°F ambient, 122°F condensing
KCA-F1Ammonia condenserFlat bed, one row of fans491 to 8618 to 5,302Ammonia, 95°F ambient, 122°F condensing
KCH-F1HFC condenserFlat bed, one row of fans711 to 7785 to 6,551R404A, 95°F ambient, 122°F condensing
KCA-F1Ammonia condenserFlat bed, one row of fans711 to 7894 to 6,777Ammonia, 95°F ambient, 122°F condensing
KCH-F2HFC condenserFlat bed, two rows of fans364 to 18972 to 5,569R404A, 95°F ambient, 122°F condensing
KCA-F2Ammonia condenserFlat bed, two rows of fans364 to 18515 to 5,831Ammonia, 95°F ambient, 122°F condensing
KCH-V1HFC condenserV-bank, one row of fans361 to 10293 to 3,982R404A, 95°F ambient, 122°F condensing
KCA-V1Ammonia condenserV-bank, one row of fans361 to 10317 to 4,211Ammonia, 95°F ambient, 122°F condensing
KCH-V1HFC condenserV-bank, one row of fans491 to 10723 to 7,984R404A, 95°F ambient, 122°F condensing
KCA-V1Ammonia condenserV-bank, one row of fans491 to 10686 to 8,111Ammonia, 95°F ambient, 122°F condensing
KCH-V1HFC condenserV-bank, one row of fans631 to 101,440 to 13,939R404A, 95°F ambient, 122°F condensing
KCA-V1Ammonia condenserV-bank, one row of fans631 to 101,491 to 15,078Ammonia, 95°F ambient, 122°F condensing
KCH-V2HFC condenserV-bank, two rows of fans364 to 281,157 to 10,816R404A, 95°F ambient, 122°F condensing
KCA-V2Ammonia condenserV-bank, two rows of fans364 to 281,218 to 11,188Ammonia, 95°F ambient, 122°F condensing
Frames, flat bed, one fan row23 frames
FrameFansFan, inLength, inWidth, inHeight, in
F1-01x3613678 or 904869
F1-02x36236137 or 1614869
F1-03x36336196 or 2314869
F1-04x36436255 or 3024869
F1-05x36536314 or 3734869
F1-06x36636373 or 4444869
F1-07x36736432 or 5154869
F1-08x36836491 or 5864869
F1-01x4914910290–
F1-02x4924918190–
F1-03x4934926090–
F1-04x4944933990–
F1-05x4954941790–
F1-06x4964949690–
F1-07x4974957590–
F1-08x4984965490–
F1-01x711711189085
F1-02x712712139085
F1-03x713713079085
F1-04x714714029085
F1-05x715714969085
F1-06x716715919085
F1-07x717716859085
Frames, flat bed, two fan rows8 frames
FrameFansFan, inLength, inWidth, inHeight, in
F2-04x36436137 or 1618969
F2-06x36636196 or 2318969
F2-08x36836255 or 3028969
F2-10x361036314 or 3738969
F2-12x361236373 or 4448969
F2-14x361436432 or 5158969
F2-16x361636491 or 5868969
F2-18x361836550 or 6578969
Frames, V-bank, one fan row30 frames
FrameFansFan, inLength, inWidth, inHeight, in
V1-01x36136604568
V1-02x362361074568
V1-03x363361554568
V1-04x364362024568
V1-05x365362494568
V1-06x366362964568
V1-07x367363444568
V1-08x368363914568
V1-09x369364384568
V1-10x3610364854568
V1-01x49149767993
V1-02x492491397993
V1-03x493492027993
V1-04x494492657993
V1-05x495493287993
V1-06x496493917993
V1-07x497494547993
V1-08x498495177993
V1-09x499495807993
V1-10x4910496437993
V1-01x63163110106121
V1-02x63263205106121
V1-03x63363299106121
V1-04x63463394106121
V1-05x63563488106121
V1-06x63663583106121
V1-07x63763677106121
V1-08x63863772106121
V1-09x63963866106121
V1-10x631063961106121
Frames, V-bank, two fan rows13 frames
FrameFansFan, inLength, inWidth, inHeight, in
V2-04x3643610789 or 11097
V2-06x3663615589 or 11097
V2-08x3683620289 or 11097
V2-10x36103624989 or 11097
V2-12x36123629689 or 11097
V2-14x36143634489 or 11097
V2-16x36163639189 or 11097
V2-18x36183643889 or 11097
V2-20x36203648589 or 11097
V2-22x36223653389 or 11097
V2-24x36243658089 or 11097
V2-26x36263662789 or 11097
V2-28x36283667489 or 11097

Questions buyers ask

All questions

What is an air-cooled condenser?

An air-cooled condenser rejects the heat from a refrigeration system to outdoor air. Hot refrigerant gas from the compressor condenses to liquid inside a finned coil while fans move air across it.

What capacity do KUHLWERX condensers cover?

249 to 13,939 MBH heat rejection on HFC, rated R404A, and 246 to 15,078 MBH on ammonia, both at 95°F ambient and 122°F condensing.

Flat bed or V-bank?

A V-bank puts the coils in a V under the fans, so it fits more coil surface in the same footprint. Flat bed units are lower and simpler to service. Footprint, sound and capacity decide it.

Request a quote

Send us the heat load.

Fluid, flow, ambient and the space you have. A sized selection comes back with the approval marks confirmed.

Request a Quote

A person reads it. Send the heat load and a selection comes back.